Greenhouse Winter Heater Sizing (BTU/hr) & Glazing U-Factor Calculator: inputs, method, and how to read the result
Size greenhouse heaters using Q = U × ExposedSurfaceArea × ΔT.
Choose inputs for the case you are checking
The defaults are illustrative. Replace them with values for your case and keep the units shown beside each field.
- Exposed Glazing Area Sq Ft: Total exposed roof, sidewall, and endwall glazing area in sq ft.
- Glazing U Factor: Glazing heat transfer coefficient U (1.1 single glass, 0.7 twin-wall poly, 0.55 double poly).
- Inside Target Temp F: Minimum desired winter night temperature inside greenhouse (°F).
- Outside Min Design Temp F: Coldest outdoor winter design temperature (°F).
What the calculation includes
With the default values shown, Required Heater Input Rating is 65,731.71 BTU/hr. The calculation follows Greenhouse Heater BTU Formula; the formula and variable definitions above show how the inputs combine.
One-input check: With the other defaults held constant, changing Exposed Glazing Area Sq Ft from 1,400 sq ft to 1,540 sq ft changes Required Heater Input Rating from 65,731.71 BTU/hr to 72,304.88 BTU/hr. This is a comparison inside the calculator's stated model, not a prediction.
Where to use caution
- Uses standard North American & metric trade dimensions, Machinery’s Handbook formulas, and culinary weight ratios.
- Verify local municipal building codes, tool manufacturer limits, and food-safety time/temperature tables before execution.
Scope: Trade, Shop & Culinary Science Reference Standard Check the assumptions and limitations against your situation before relying on the estimate.